-- XML schema extracted from ITU-T H.860 (04/2014)
<!-- ITU-T H.810 CERTIFIED THERMOMETER DATA OUTPUT IN HL7 R2 MESSAGE FORMAT -->
<section>
<templateId root="2.16.840.1.113883.10.20.1.7"/>
<templateId root="2.16.840.1.113883.10.20.9.1"/>
<code code="46264-8" codeSystem="2.16.840.1.113883.6.1"/><!--LOINC code 46264-8 “Medical Equipment” -->
<title>Medical Equipment</title>
<text>
<!-- Device information -->
<table border="1" width="100%">
<tbody>
<tr>
<th>System Type</th>
<th>System Model</th>
<th>System Manufacturer</th>
<th>System ID</th>
<th>Production Spec</th>
<th>Regulated</th>
</tr>
<tr>
<td>Blood Pressure Monitor</td>
<td>Pulse Master 2000</td>
<td>Acme</td>
<td>1F-3E-46-78-9A-BC-DE-F1</td>
<td>
Unspecified:
Serial Number: 584216<br/>
Part Number: 69854<br/>
Hardware Revision: 2.1<br/>
Software Revision: 1.1<br/>
Protocol Revision: 1.0<br/>
Prod Spec GMDN:
</td>
<td>Regulated</td>
</tr>
</tbody>
</table>
</text>
<entry typeCode="COMP">
<organizer classCode="CLUSTER" moodCode="EVN">
<templateId root="2.16.840.1.113883.10.20.9.4"/>
<statusCode code="completed"/>
<effectiveTime value="20080801104033-0600"/><!-- 2008/08/01 10:40:33 -->
<participant typeCode="SBJ">
<participantRole classCode="MANU">
<templateId root="2.16.840.1.113883.10.20.1.52"/>
<templateId root="2.16.840.1.113883.10.20.9.9"/>
<id root="1.2.840.10004.1.1.1.0.0.1.0.0.1.2680" assigningAuthorityName="EUI-64" extension="1A-34-46-78-9A-BC-DE-F3"/><!-- Unique Identifier (IMEI) -->
<code nullFlavor="OTH">
<originalText>Regulated Device</originalText>
</code>
<playingDevice>
<code code="MDC_DEV_SPEC_PROFILE_BPM" codeSystem="2.16.840.1.113883.6.24" codeSystemName="MDC" displayName="Blood Pressure Monitor"><!-- ISO/IEEE 11073 MDC_DEV_SPEC_PROFILE_BPM "Blood Pressure Monitor" -->
<translation code="32033000" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED CT" displayName="Arterial pressure monitor"/><!-- SNOMED code 32033000 “Arterial Pressure Monitor -->
<translation code="???" codeSystem="GMDN-OID">
<!-- move Production spec GMDN here from the manufacturerModelName-->
</translation>
</code>
<code code="MDC_DEV_SPEC_PROFILE_BPM" codeSystem="2.16.840.1.113883.6.24" codeSystemName="MDC" displayName="Blood Pressure Monitor"><!-- ISO/IEEE 11073 MDC_DEV_SPEC_PROFILE_BPM "Blood Pressure Monitor" -->
<translation code="32033000" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED CT" displayName="Arterial pressure monitor"/><!-- SNOMED code 32033000 “Arterial Pressure Monitor -->
</translation>
</code>
<manufacturerModelName>
<!-- these will be unstructured, the text below is an example (no shalls for the labels used below)-->
Model: Pulse Master 2000
Serial number:584216
Part number: 69854
Hardware revision: 2.1
Software revision: 1.1
Protocol revision: 1.0
Unspecified (free text comment):
</manufacturerModelName>
</playingDevice>
<scopingEntity>
<desc>Acme</desc>
</scopingEntity>
</participantRole>
</participant>
<component>
<observation classCode="OBS" moodCode="EVN">
<!--... all our device observations go here -->
<code/>
</observation>
</component>
</organizer>
</entry>
</section>
<!-- Observation information -->
<section>
<templateId root="2.16.840.1.113883.10.20.1.16"/>
<templateId root="2.16.840.1.113883.10.20.9.2"/>
<code code="8716-3" codeSystem="2.16.840.1.113883.6.1"/><!-- LOINC code 8716-3 “Vital Signs” -->
<title>Vital Signs</title>
<text>
<paragraph>Thermometer Results</paragraph>
<table border="1" width="100%">
<tBody>
<tr>
<th>Date/Time</th>
<th>Body Temp</th>
<th>Finger Temp</th>
<th>Oral Temp</th>
</tr>
<tr>
<td>20080501104033</td>
<td>99.9 deg F</td>
<td>88.8 deg F</td>
<td>37.5 deg C</td>
</tr>
</tBody>
</table>
</text>
<entry typeCode="DRIV">
<organizer classCode="CLUSTER" moodCode="EVN">
<!-- Vital sign data/ Test Groups -->
<!-- A VITAL SIGNS ORGANIZER IS USED TO GROUP RELATED -->
<templateId root="2.16.840.1.113883.10.20.1.35"/>
<id root="b606a959-baab-4836-84a8-97c4e9857533"/>
<code code="46680005" codeSystem="2.16.840.1.113883.6.96" displayName="Vital signs"/><!-- SNOMED code 46680005 “Vital Signs” -->
<statusCode code="completed"/>
<component>
<observation classCode="OBS" moodCode="EVN">
<templateId root="2.16.840.1.113883.10.20.1.31"/>
<id root="975c2f3b-2bd4-4e45-aed1-84af9ff51b10"/>
<code code="386725007" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED CT" displayName="Body Temperature"><!-- SNOMED code 386725007 “Body Temperature” -->
<translation code="MDC_TEMP_BODY" codeSystem="2.16.840.1.113883.6.24" codeSystemName="MDC" displayName="Body Temperature"/><!-- ISO/IEEE 11073 MDC_TEMP_BODY "Body Temperature" -->
</code>
<statusCode code="completed"/>
<effectiveTime value="20080501104033-0600"/><!—2008/05/01 10:40:33 -->
<value xsi:type="PQ" value="99.9" unit="[degF]"/><!—99.9 F -->
<participant typeCode="DEV">
<participantRole>
<id root="1.2.840.10004.1.1.1.0.0.1.0.0.1.2680" assigningAuthorityName="EUI-64" extension="1A-34-46-78-9A-BC-DE-F3"/>
</participantRole>
</participant>
</observation>
</component>
<component>
<observation classCode="OBS" moodCode="EVN">
<templateId root="2.16.840.1.113883.10.20.1.31"/>
<templateId root="2.16.840.1.113883.10.20.9.8"/>
<id root="975c2f3b-2bd4-4e45-aed1-84af9ff51b10"/>
<code code="433588001" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED CT" displayName="Temperature of digit of hand"><!-- SNOMED code 433588001 “Temperature of digit of hand” -->
<translation code="MDC_TEMP_FINGER" codeSystem="2.16.840.1.113883.6.24" codeSystemName="MDC" displayName="Finger Temperature"/> "/><!-- ISO/IEEE 11073 MDC_TEMP_FINGER "Finger Temperature" -->
</code>
<statusCode code="completed"/>
<effectiveTime value="20080501104033-0600"/><!—2008/05/01 10:40:33 -->
<value xsi:type="PQ" value="88.8" unit="[degF]"/><!—88.8 F -->
<participant typeCode="DEV">
<participantRole>
<id root="1.2.840.10004.1.1.1.0.0.1.0.0.1.2680" assigningAuthorityName="EUI-64" extension="1A-34-46-78-9A-BC-DE-F3"/>
</participantRole>
</participant>
</observation>
</component>
<component>
<observation classCode="OBS" moodCode="EVN">
<templateId root="2.16.840.1.113883.10.20.1.31"/>
<templateId root="2.16.840.1.113883.10.20.9.8"/>
<id root="975c2f3b-2bd4-4e45-aed1-84af9ff51b10"/>
<code code="415945006" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED CT" displayName="Oral Temperature"><!-- SNOMED code 415945006 “Oral Temperature” -->
<translation code="MDC_TEMP_ORAL" codeSystem="2.16.840.1.113883.6.24" codeSystemName="MDC" displayName="Oral Temperature"/><!-- ISO/IEEE 11073 MDC_TEMP_ORAL "Oral Temperature" -->
</code>
<statusCode code="completed"/>
<effectiveTime value="20080501104033-0600"/><!—2008/05/01 10:40:33 -->
<value xsi:type="PQ" value="37.5" unit="Cel"/><!—37.5 C -->
<participant typeCode="DEV">
<participantRole>
<id root="1.2.840.10004.1.1.1.0.0.1.0.0.1.2680" assigningAuthorityName="EUI-64" extension="1A-34-46-78-9A-BC-DE-F3"/>
</participantRole>
</participant>
</observation>
</component>
</organizer>
</entry>
</section>