-- XML schema extracted from ITU-T H.860 (04/2014)

<!-- ITU-T H.810 CERTIFIED THERMOMETER DATA OUTPUT IN HL7 R2 MESSAGE FORMAT --> <section> <templateId root="2.16.840.1.113883.10.20.1.7"/> <templateId root="2.16.840.1.113883.10.20.9.1"/> <code code="46264-8" codeSystem="2.16.840.1.113883.6.1"/><!--LOINC code 46264-8 “Medical Equipment” --> <title>Medical Equipment</title> <text> <!-- Device information --> <table border="1" width="100%"> <tbody> <tr> <th>System Type</th> <th>System Model</th> <th>System Manufacturer</th> <th>System ID</th> <th>Production Spec</th> <th>Regulated</th> </tr> <tr> <td>Blood Pressure Monitor</td> <td>Pulse Master 2000</td> <td>Acme</td> <td>1F-3E-46-78-9A-BC-DE-F1</td> <td> Unspecified: Serial Number: 584216<br/> Part Number: 69854<br/> Hardware Revision: 2.1<br/> Software Revision: 1.1<br/> Protocol Revision: 1.0<br/> Prod Spec GMDN: </td> <td>Regulated</td> </tr> </tbody> </table> </text> <entry typeCode="COMP"> <organizer classCode="CLUSTER" moodCode="EVN"> <templateId root="2.16.840.1.113883.10.20.9.4"/> <statusCode code="completed"/> <effectiveTime value="20080801104033-0600"/><!-- 2008/08/01 10:40:33 --> <participant typeCode="SBJ"> <participantRole classCode="MANU"> <templateId root="2.16.840.1.113883.10.20.1.52"/> <templateId root="2.16.840.1.113883.10.20.9.9"/> <id root="1.2.840.10004.1.1.1.0.0.1.0.0.1.2680" assigningAuthorityName="EUI-64" extension="1A-34-46-78-9A-BC-DE-F3"/><!-- Unique Identifier (IMEI) --> <code nullFlavor="OTH"> <originalText>Regulated Device</originalText> </code> <playingDevice> <code code="MDC_DEV_SPEC_PROFILE_BPM" codeSystem="2.16.840.1.113883.6.24" codeSystemName="MDC" displayName="Blood Pressure Monitor"><!-- ISO/IEEE 11073 MDC_DEV_SPEC_PROFILE_BPM "Blood Pressure Monitor" --> <translation code="32033000" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED CT" displayName="Arterial pressure monitor"/><!-- SNOMED code 32033000 “Arterial Pressure Monitor --> <translation code="???" codeSystem="GMDN-OID"> <!-- move Production spec GMDN here from the manufacturerModelName--> </translation> </code> <code code="MDC_DEV_SPEC_PROFILE_BPM" codeSystem="2.16.840.1.113883.6.24" codeSystemName="MDC" displayName="Blood Pressure Monitor"><!-- ISO/IEEE 11073 MDC_DEV_SPEC_PROFILE_BPM "Blood Pressure Monitor" --> <translation code="32033000" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED CT" displayName="Arterial pressure monitor"/><!-- SNOMED code 32033000 “Arterial Pressure Monitor --> </translation> </code> <manufacturerModelName> <!-- these will be unstructured, the text below is an example (no shalls for the labels used below)--> Model: Pulse Master 2000 Serial number:584216 Part number: 69854 Hardware revision: 2.1 Software revision: 1.1 Protocol revision: 1.0 Unspecified (free text comment): </manufacturerModelName> </playingDevice> <scopingEntity> <desc>Acme</desc> </scopingEntity> </participantRole> </participant> <component> <observation classCode="OBS" moodCode="EVN"> <!--... all our device observations go here --> <code/> </observation> </component> </organizer> </entry> </section> <!-- Observation information --> <section> <templateId root="2.16.840.1.113883.10.20.1.16"/> <templateId root="2.16.840.1.113883.10.20.9.2"/> <code code="8716-3" codeSystem="2.16.840.1.113883.6.1"/><!-- LOINC code 8716-3 “Vital Signs” --> <title>Vital Signs</title> <text> <paragraph>Thermometer Results</paragraph> <table border="1" width="100%"> <tBody> <tr> <th>Date/Time</th> <th>Body Temp</th> <th>Finger Temp</th> <th>Oral Temp</th> </tr> <tr> <td>20080501104033</td> <td>99.9 deg F</td> <td>88.8 deg F</td> <td>37.5 deg C</td> </tr> </tBody> </table> </text> <entry typeCode="DRIV"> <organizer classCode="CLUSTER" moodCode="EVN"> <!-- Vital sign data/ Test Groups --> <!-- A VITAL SIGNS ORGANIZER IS USED TO GROUP RELATED --> <templateId root="2.16.840.1.113883.10.20.1.35"/> <id root="b606a959-baab-4836-84a8-97c4e9857533"/> <code code="46680005" codeSystem="2.16.840.1.113883.6.96" displayName="Vital signs"/><!-- SNOMED code 46680005 “Vital Signs” --> <statusCode code="completed"/> <component> <observation classCode="OBS" moodCode="EVN"> <templateId root="2.16.840.1.113883.10.20.1.31"/> <id root="975c2f3b-2bd4-4e45-aed1-84af9ff51b10"/> <code code="386725007" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED CT" displayName="Body Temperature"><!-- SNOMED code 386725007 “Body Temperature” --> <translation code="MDC_TEMP_BODY" codeSystem="2.16.840.1.113883.6.24" codeSystemName="MDC" displayName="Body Temperature"/><!-- ISO/IEEE 11073 MDC_TEMP_BODY "Body Temperature" --> </code> <statusCode code="completed"/> <effectiveTime value="20080501104033-0600"/><!—2008/05/01 10:40:33 --> <value xsi:type="PQ" value="99.9" unit="[degF]"/><!—99.9 F --> <participant typeCode="DEV"> <participantRole> <id root="1.2.840.10004.1.1.1.0.0.1.0.0.1.2680" assigningAuthorityName="EUI-64" extension="1A-34-46-78-9A-BC-DE-F3"/> </participantRole> </participant> </observation> </component> <component> <observation classCode="OBS" moodCode="EVN"> <templateId root="2.16.840.1.113883.10.20.1.31"/> <templateId root="2.16.840.1.113883.10.20.9.8"/> <id root="975c2f3b-2bd4-4e45-aed1-84af9ff51b10"/> <code code="433588001" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED CT" displayName="Temperature of digit of hand"><!-- SNOMED code 433588001 “Temperature of digit of hand” --> <translation code="MDC_TEMP_FINGER" codeSystem="2.16.840.1.113883.6.24" codeSystemName="MDC" displayName="Finger Temperature"/> "/><!-- ISO/IEEE 11073 MDC_TEMP_FINGER "Finger Temperature" --> </code> <statusCode code="completed"/> <effectiveTime value="20080501104033-0600"/><!—2008/05/01 10:40:33 --> <value xsi:type="PQ" value="88.8" unit="[degF]"/><!—88.8 F --> <participant typeCode="DEV"> <participantRole> <id root="1.2.840.10004.1.1.1.0.0.1.0.0.1.2680" assigningAuthorityName="EUI-64" extension="1A-34-46-78-9A-BC-DE-F3"/> </participantRole> </participant> </observation> </component> <component> <observation classCode="OBS" moodCode="EVN"> <templateId root="2.16.840.1.113883.10.20.1.31"/> <templateId root="2.16.840.1.113883.10.20.9.8"/> <id root="975c2f3b-2bd4-4e45-aed1-84af9ff51b10"/> <code code="415945006" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED CT" displayName="Oral Temperature"><!-- SNOMED code 415945006 “Oral Temperature” --> <translation code="MDC_TEMP_ORAL" codeSystem="2.16.840.1.113883.6.24" codeSystemName="MDC" displayName="Oral Temperature"/><!-- ISO/IEEE 11073 MDC_TEMP_ORAL "Oral Temperature" --> </code> <statusCode code="completed"/> <effectiveTime value="20080501104033-0600"/><!—2008/05/01 10:40:33 --> <value xsi:type="PQ" value="37.5" unit="Cel"/><!—37.5 C --> <participant typeCode="DEV"> <participantRole> <id root="1.2.840.10004.1.1.1.0.0.1.0.0.1.2680" assigningAuthorityName="EUI-64" extension="1A-34-46-78-9A-BC-DE-F3"/> </participantRole> </participant> </observation> </component> </organizer> </entry> </section>