本勘误处理P.862.2中主观得分系统性预测偏低问题。造成偏低预测值(0.8 MOS)的原因是由于暴露的音频信号与响度模型不匹配。此问题导致劣化被夸大,得出低于预期值的分数。P.862.2参考实施的下述更新将信号调至用于宽带评估的76 dB(SPL)目标电平:– pesqmain.c, line 421: float WB_InIIR_Hsos_8k[LINIIR] = { 0.251188 * 2.6657628f, 0.251188 * -5.3315255f, 0.251188 * 2.6657628f, -1.8890331f, 0.89487434f };– pesqmain.c, line 424: float WB_InIIR_Hsos_16k[LINIIR] = { 0.251188 * 2.740826f, 0.251188 * -5.4816519f, 0.251188 * 2.740826f, -1.9444777f, 0.94597794f };P.862.2更新后的一致性测试文件已纳入本勘误 (suppl23_wb.txt)。 |
|
Citation: |
https://handle.itu.int/11.1002/1000/13398 |
Series title: |
|
Approval date: |
2017-10-29 |
Provisional name: | P.WBPESQ |
Approval process: | AAP |
Status: |
Superseded |
Observation: | Publication of this corrigendum has temporarily been placed on hold |
Maintenance responsibility: |
ITU-T Study Group 12 |
Further details: |
Patent statement(s)
Development history
|
|
|
|