CONTENTS

 1     Scope, purpose, and field of application
        1.1     Scope
        1.2     Purpose
        1.3     Field of application
        1.4     Structure of this Recommendation
 2     Overview of the network model
 3     Object classes
        3.1     Network fragment
        3.2     Managed element fragment
        3.3     Termination point fragment
        3.4     Switching and transmission fragment
        3.5     Cross-connection fragment
        3.6     Functional area fragment
 4     Packages
        4.1     Administrative Operational States
        4.2     Affected Object List
        4.3     Alarm Severity Assignment Pointer
        4.4     Attribute Value Change Notification
        4.5     Audible Visual Local Alarm
        4.6     Channel Number
        4.7     Characteristic Information
        4.8     Client Connection List
        4.9     Client Trail
       4.10     Create Delete Notifications
       4.11     Cross-Connection Pointer
       4.12     CTP Instance
       4.13     Current Problem List
       4.14     Environmental Alarm
       4.15     Environmental AlarmR1
       4.16     Equipment Alarm Effect on Service
       4.17     Equipments Equipment Alarm
       4.18     Equipments Equipment AlarmR1
       4.19     External Time
       4.20     Location Name
       4.21     Named Cross-Connection
       4.22     Network Level
       4.23     Operational State
       4.24     Object Management Notifications
       4.25     Processing Error Alarm
       4.26     Processing Error AlarmR1
       4.27     Protected
       4.28     Reset Audible Alarm
       4.29     Server Connection List
       4.30     Server Trail List
       4.31     Software Processing Error Alarm
       4.32     Software Processing Error AlarmR1
       4.33     Subordinate Circuit Pack
       4.34     Supportable Client List
       4.35     State Change Notification
       4.36     System Timing Source
       4.37     TMN Communications Alarm Information
       4.38     TTP Instance
       4.39     User Label
       4.40     Vendor Name
       4.41     Version
 5     Attributes
        5.1     A-Termination Point Instance
        5.2     Acceptable Circuit Pack Type List
        5.3     Administrative State
        5.4     Affected Object List
        5.5     Alarm Severity Assignment List
        5.6     Alarm Severity Assignment Profile Id
        5.7     Alarm Severity Assignment Profile Pointer
        5.8     Alarm Status
        5.9     Channel Number
       5.10     Characteristic Information
       5.11     Circuit Directionality
       5.12     Circuit End Point Subgroup Id
       5.13     Circuit Pack Type
       5.14     Client Connection List
       5.15     Client Trail
       5.16     Connected Termination Point Count
       5.17     Connection Id
       5.18     Connection Termination Point Id
       5.19     Cross-Connection Id
       5.20     Cross-Connection Name
       5.21     Cross-Connection Object Pointer
       5.22     Current Problem List
       5.23     Directionality
       5.24     Downstream Connectivity Pointer
       5.25     Equipment Holder Address
       5.26     Equipment Holder Type
       5.27     Equipment Id
       5.28     External Time
       5.29     Fabric Id
       5.30     From Termination
       5.31     Group Termination Point Id
       5.32     Holder Status
       5.33     Idle TP Count
       5.34     Information Transfer Capabilities
       5.35     Label of Far End Exchange
       5.36     List of Characteristic Info
       5.37     Location Name
       5.38     Managed Element Id
       5.39     Managed Element Complex Id
       5.40     Multi-Point Cross-Connection Id
       5.41     Network Id
       5.42     Network Level Pointer
       5.43     Number of Circuits
       5.44     Operational State
       5.45     Protected
       5.46     Redline
       5.47     Replaceable
       5.48     Serial Number
       5.49     Server Connection List
       5.50     Server Trail List
       5.51     Signalling Capabilities
       5.52     Signal Type
       5.53     Software Id
       5.54     Subordinate Circuit Pack Software Load
       5.55     Supportable Client List
       5.56     Supported By Object List
       5.57     System Timing Source
       5.58     System Title
       5.59     Total TP Count
       5.60     To Termination
       5.61     TP Pool Id
       5.62     TPs In GTP List
       5.63     TPs In TP Pool List
       5.64     Trail Id
       5.65     Trail Termination Point Id
       5.66     Transmission Characteristics
       5.67     Upstream Connectivity Pointer
       5.68     Usage State
       5.69     User Label
       5.70     Vendor Name
       5.71     Version
       5.72     Z-Termination Point Instance
 6     Name Bindings
        6.1     Alarm Record
        6.2     Alarm Severity Assignment Profile
        6.3     Circuit Pack
        6.4     ConnectionR1
        6.5     Connection Termination Point Source
        6.6     Connection Termination Point Sink
        6.7     Cross-Connection
        6.8     Equipment
        6.9     Equipment Holder
       6.10     Event Forwarding Discriminator
       6.11     Fabric
       6.12     GTP
       6.13     Log
       6.14     Managed Element
       6.15     Managed Element Complex
       6.16     Multi-Point Cross-Connection
       6.17     Network
       6.18     Software
       6.19     TP Pool
       6.20     TrailR1
       6.21     Trail Termination Point Source
       6.22     Trail Termination Point Sink
 7     Actions
        7.1     Add TPs To GTP
        7.2     Add TPs To TP Pool
        7.3     Allow Audible Visual Local Alarm
        7.4     Connect
        7.5     Disconnect
        7.6     Inhibit Audible Visual Local Alarm
        7.7     Remove TPs From GTP
        7.8     Remove TPs From TP Pool
        7.9     Reset Audible Alarm
       7.10     Switch Over
 8     Notifications
        8.1     Attribute Value Change
        8.2     Communications Alarm
        8.3     Environmental Alarm
        8.4     Equipment Alarm
        8.5     Object Creation
        8.6     Object Deletion
        8.7     Processing Error Alarm
        8.8     State Change
 9     Parameters
        9.1     Alarm Effect On Service Parameter
        9.2     Create Error
10     ASN.1 defined types module
       10.1     Rules of Extensibility
       10.2     ASN.1 Module
11     TMN application context
12     Entity-Relationship diagrams
Annex A  –  Index
        A.1     Managed objects
        A.2     Packages
        A.3     Attributes
        A.4     Name bindings
        A.5     Actions
        A.6     Notifications
        A.7     Parameters
Appendix I  –  User guidelines
        I.1     Introduction
        I.2     Use of supported by object list
        I.3     Use of upstream and downstream connectivity pointers
        I.4     Use of cross-connection objects
        I.5     Cross-connection use examples
        I.6     Object classes and logical layering
        I.7     Mandatory naming attribute
        I.8     Interoperability between Recommendation M.3100 (1992) and this Recommendation
        I.9     Support for multi-point trails
Appendix II  –  Deprecated/obsolete management information from Recommendation M.3100 (1992)
       II.1     Object classes
       II.2     Packages
       II.3     Attributes
       II.4     Name binding
Appendix III  –  Differences from Recommendation M.3100 (1992)
References